| You are here: Home
» Solutions
for users » The room system in detail |
Height adjustment + wall fixture |
Height adjustment with profile connectors
During pre-assembly insert the profile connnectors into the suppporting
profile up to 10 mm and tighten with system screws.
Adjustment - 10 mm to + 30 mm possible. |
 |
| |
Height adjustment with
elevating insert
For use of load-bearing joint profiles with holes.
Profile connectors are fully pushed into the supporting profiles and
tightened during pre-assembly.
The elevating inserts (screw 8x50 and slot nut) are used next to the
supporting profile. The joint profile must make contact with the floor
profile. |
 |
| |
Wall fixing with 3D fittings
Pre-assembly of the 3D fasteners in the cross-slots of the supporting
profiles. M8 nut and washer at same height (= supporting profile length).
Distance approx.896 mm.
Dowel fixing to the wall through the slots on the base plate. (through
fixing). Washer required under screw head! With very uneven walls
use underlying base plate.
Fine adjustment in wall direction 10 mm max.
- Release nut
- Adjust the collar screw to the right depth with a screwdriver
- Retighten the nut
Max. lateral adjustment in the supporting profile slot 12
mm.
- Release nut
- Shift profile
- Retighten the nut
Height adjustment 12 mm.
- Release the wall fixture screws
- Adjust the height
- Retighten the screws
Wall spacer is supplied without adjustment insert and must be equipped
with a (M8) threaded bolt
of the required length. |

 |
| |
|
| |
| Further information "The
room system in detail" |
|
| |
| Further information |
|